![]() |
Profile | Contact Us | Links |
||
|
NEW ADVERC ABM SOLENOID SYSTEMINTELLIGENT SPLIT CHARGING
The ABM allows multiple batteries to be charged from one source. The ABM is designed for use in multi-battery applications as a priority system to protect the chassis charging system from excessive loading whilst allowing auxiliary batteries to be charged. It has two basic operational characteristics: Intelligent Split Charging The unit monitors the battery system to determine if the batteries are being charged. When the engine or auxiliary batteries reach the correct voltage it will join the two battery banks. If the drain on the charging system by the auxiliary or the vehicle battery bank reduces the system voltage significantly, the unit will disconnect the battery banks from each other, thus protecting the respective battery banks from excessive drain. A delay function has been incorporated in the control circuit to prevent the ABM from reacting to momentary voltage fluctuations and chattering. Assist in engine starting If the vehicle battery is discharged it can be linked with the auxiliary bank to assist with starting. Simple Installation Connects to vehicle battery, auxiliary battery and negative. No system modifications necessary. Download a sample schematic here (PDF Format) For further information on ONEbox configurations, please contact us. |
||||||||||||||||||||||||||||||||||||